Fluxomatic® Corona Discharge Treater

Achieve perfect treatment for perfect bonding....

Corona Treatment is a process of high speed oxidation which creates polar molecules on the film surface. The energy of the corona will break the bonds of the atomic structure of the substrate. The oxygen rich ozone developed by the corona discharge readily fills the open valancies which create a charge surface thus improving the surface characteristics. The Treated surface tends to go back to it's original dyne level after a certain period of time. This Decay of Treatment is exponential in nature and varies for different type of materials, it's additive content and other factors. Proper packaging reduces the rate of decay. Generally the effect of treatment remains for about a month.

Fluxomatic® Corona Treater

Corona Treatment for Blown Films

Specification

Treatment Width: 625mm.

Roller Width: 675mm.

Read MoreRequest Quote

FTS 500(Printing)

Specification Sheet

Treatment Width: 625mm.

Roller Width: 675mm.

Line Speed: 40 meters per minute.

Dyne Level: 38 Dynes/cm.

No of Sides: Double.

Substrate: HDPE, LDPE, LLDPE and PP.

Gauge: 40-100 microns.

Generator

Electrical Input Requirements: 230VAC | Single Phase | 50Hz | 5 Amps.

Output Power: 500 Watts.

Output Frequency: 20–40 Khz.

Transformer

MOC: MS Powder Coated.

Output Voltage: 10 K Volts.

Interlocks: Spark Gap Interlock which trips the Generator when the Discharge Station High Voltage Wire Breaks during Operation.

Cooling: Transformer Oil [IS 335] | Quantity : 15 Litres

Pneumatic Operated Split Box Assembly

Electrodes: SS Pipe Type Electrode/ Key Type*.

Treating Rollers: 50mm Roller covered with Pure Silicon Sleeve

Guide Rollers: 50mm rollers for Entry & Exit of Film.

Safety Interlocks

Zero Speed System: In case the Guide or Main Roller stops moving , the Generator Trips.

Spark Protection: In case of Spark in the Electrodes, the Generator will Trip.

Phase Protection: NA

Discharge Station Door Open Interlock: When the Door Opens, the Generator will trip.

No Corona Interlock: In case of No Corona, A Visual / Audio Indication will be given.

Accessories

Cables: As per Installation Requirements.

Dyne Level Pens: 38 Dynes Disposable Pen.

Note: Design and Specifications are subjected to change without prior notice.

FTS 500(Printing)

FTS 500(Printing)

Specification

Treatment Width: 625mm.

Roller Width: 675mm.

Read MoreRequest Quote

FTS 650(Printing)

Specification Sheet

Treatment Width: 625mm.

Roller Width: 675mm.

Line Speed: 80 meters per minute.

Dyne Level: 38 Dynes/cm.

No of Sides: Double.

Substrate: HDPE, LDPE, LLDPE and PP.

Gauge: 40-100 microns.

Generator

Electrical Input Requirements: 230VAC | Single Phase | 50Hz | 5 Amps.

Output Power: 750 Watts.

Output Frequency: 20–40 Khz.

Transformer

MOC: Aluminium Powder Coated.

Output Voltage: 10 K Volts.

Interlocks: Spark Gap Interlock which trips the Generator when the Discharge Station High Voltage Wire Breaks during Operation.

Cooling: Transformer Oil [IS 335] | Quantity : 20 Litres

Pneumatic Operated Split Box Assembly

Electrodes: SS Pipe Type Electrode/ Key Type.

Treating Rollers: Two 75mm Rollers covered with Pure Dielectric Silicon Sleeve.

Guide Rollers: 50mm rollers for Entry & Exit of Film.

Safety Interlocks

Zero Speed System: In case the Guide or Main Roller stops moving , the Generator Trips.

Spark Protection: In case of Spark in the Electrodes, the Generator will Trip.

Phase Protection: NA

Discharge Station Door Open Interlock: When the Door Opens, the Generator will trip.

No Corona Interlock: In case of No Corona, A Visual / Audio Indication will be given.

Ozone Extraction System

Motors: 1 HP | 3 Phase | 415 V | 15 Amps.

Suction Capacity: 300 CFM.

Pressure: 6”.

Inlet: 2 x 50mm.

Outlet: 75mm.

Accessories

Cables: As per Installation Requirements.

Dyne Level Pens: 38 Dynes Disposable Pen.

Note: Design and Specifications are subjected to change without prior notice.

FTS 650(Printing)

FTS 650(Printing)

Specification

Treatment Width: 850mm.

Roller Width: 850mm.

Read MoreRequest Quote

FTS 750(Printing)

Specification Sheet

Treatment Width: 850mm.

Roller Width: 850mm.

Line Speed: 80 meters per minute.

Dyne Level: 38 Dynes/cm.

No of Sides: Double.

Substrate: HDPE, LDPE, LLDPE and PP.

Gauge:

Generator

Electrical Input Requirements: 230VAC | Single Phase | 50Hz | 5 Amps.

Output Power: 750 Watts.

Output Frequency: 20–40 Khz.

Transformer

MOC: Aluminium Powder Coated.

Output Voltage: 10 K Volts.

Interlocks: Spark Gap Interlock which trips the Generator when the Discharge Station High Voltage Wire Breaks during Operation.

Cooling: Transformer Oil [IS 335] | Quantity : 20 Litres

Pneumatic Operated Split Box Assembly

Electrodes: SS Pipe Type Electrode/ Key Type.

Treating Rollers: Two 75mm Rollers covered with Pure Dielectric Silicon Sleeve.

Guide Rollers: Two 50mm rollers for Entry & Exit of Film.

Safety Interlocks

Zero Speed System: In case the Guide or Main Roller stops moving , the Generator Trips.

Spark Protection: In case of Spark in the Electrodes, the Generator will Trip.

Phase Protection: NA

Discharge Station Door Open Interlock: When the Door Opens, the Generator will trip.

No Corona Interlock: In case of No Corona, A Visual / Audio Indication will be given.

Ozone Extraction System

Motors: 1 HP | 3 Phase | 415 V | 15 Amps.

Suction Capacity: 300 CFM.

Pressure: 6”.

Inlet: 2 x 50mm.

Outlet: 75mm.

Accessories

Cables: As per Installation Requirements.

Dyne Level Pens: 38 Dynes Disposable Pen.

Note: Design and Specifications are subjected to change without prior notice.

FTS 750(Printing)

FTS 750(Printing)

Specification

Treatment Width: 1050mm.

Roller Width: 1100mm.

Read MoreRequest Quote

FTS 1000(Printing)

Specification Sheet

Treatment Width: 1050mm.

Roller Width: 1100mm.

Line Speed: 40 meters per minute.

Dyne Level: 38 Dynes/cm.

No of Sides: Double.

Substrate: HDPE, LDPE, LLDPE and PP.

Gauge: 40-100 microns.

Generator

Electrical Input Requirements: 230VAC | Single Phase | 50Hz | 5 Amps.

Output Power: 1000 Watts.

Output Frequency: 20–40 Khz.

Transformer

MOC: Aluminium Powder Coated.

Output Voltage: 10 K Volts.

Interlocks: Spark Gap Interlock which trips the Generator when the Discharge Station High Voltage Wire Breaks during Operation.

Cooling: Transformer Oil [IS 335] | Quantity : 20 Litres

Pneumatic Operated Split Box Assembly

Electrodes: SS Pipe Type Electrode/ Key Type.

Treating Rollers: Two 75mm Rollers covered with Pure Dielectric Silicon Sleeve.

Guide Rollers: Two 50mm rollers for Entry & Exit of Film.

Safety Interlocks

Zero Speed System: In case the Guide or Main Roller stops moving , the Generator Trips.

Spark Protection: In case of Spark in the Electrodes, the Generator will Trip.

Phase Protection: NA

Discharge Station Door Open Interlock: When the Door Opens, the Generator will trip.

No Corona Interlock: In case of No Corona, A Visual / Audio Indication will be given.

Ozone Extraction System

Motors: 2 HP | 3 Phase | 415 V | 15 Amps.

Suction Capacity: 500 CFM.

Pressure: 12”.

Inlet: 2 x 50mm.

Outlet: 75mm.

Accessories

Cables: As per Installation Requirements.

Dyne Level Pens: 38 Dynes Disposable Pen.

Note: Design and Specifications are subjected to change without prior notice.

FTS 1000(Printing)

FTS 1000(Printing)

Specification

Treatment Width: 1500mm.

Roller Width: 1600mm.

Read MoreRequest Quote

FTS 3000(Printing)

Specification Sheet

Treatment Width: 1500mm.

Roller Width: 1600mm.

Line Speed: 80 meters per minute.

Dyne Level: 38 Dynes/cm.

No of Sides: Double.

Substrate: HDPE, LDPE, LLDPE and PP.

Gauge: 40-100 microns.

Generator

Electrical Input Requirements: 415VAC | 3Phase | 50Hz | 15 Amps.

Output Power: 3000 Watts.

Output Frequency: 20–40 Khz.

System with MMI Display: Schneider or Equivalent

Transformer

MOC: Aluminium.

Output Voltage: 10 K Volts.

Interlocks: Spark Gap Interlock which trips the Generator when the Discharge Station High Voltage Wire Breaks during Operation.

Cooling: Transformer Oil [IS 335] | Quantity : 25 Litres

Pneumatic Operated Split Box Assembly

Electrodes: SS Pipe Type Electrode/ Key Type.

Treating Rollers: Two 100mm Rollers covered with Pure Dielectric Silicon Sleeve.

Guide Rollers: Two 75mm rollers for Entry & Exit of Film.

Safety Interlocks

Zero Speed System: In case the Guide or Main Roller stops moving , the Generator Trips.

Spark Protection: In case of Spark in the Electrodes, the Generator will Trip.

Phase Protection: In the Event of any Phase Failure, the Generator will Switch Off Completely

Discharge Station Door Open Interlock: When the Door Opens, the Generator will trip.

No Corona Interlock: In case of No Corona, A Visual / Audio Indication will be given.

Ozone Extraction System

Motors: 3 HP | 3 Phase | 415 V | 15 Amps.

Suction Capacity: 600 CFM.

Pressure: 12”.

Inlet: 2 x 50mm.

Outlet: 75mm.

Accessories

Cables: As per Installation Requirements.

Dyne Level Pens: 38 Dynes Disposable Pen.

Note: Design and Specifications are subjected to change without prior notice.

FTS 3000(Printing)

FTS 3000(Printing)

Specification

Treatment Width: 1500mm.

Roller Width: 1600mm.

Read MoreRequest Quote

FTS 5000 Series

Specification Sheet

Treatment Width: 1500mm.

Roller Width: 1600mm.

Line Speed: 80 meters per minute.

Dyne Level: 42-44 Dynes/cm.

No of Sides: Double.

Substrate: HDPE, LDPE, LLDPE and PP.

Gauge: 40-100 microns.

Generator

Electrical Input Requirements: 415VAC | 3Phase | 50Hz | 15 Amps.

Output Power: 4000 Watts.

Output Frequency: 20–40 Khz.

PLC System with MMI Display: Unitronics or Equivalent.

Transformer

MOC: Aluminium.

Output Voltage: 10 K Volts.

Interlocks: Spark Gap Interlock which trips the Generator when the Discharge Station High Voltage Wire Breaks during Operation.

Cooling: Transformer Oil [IS 335] | Quantity : 50 Litres

Discharge Station

Electrodes: Fin Type Electrode / Key Type*.

Main Rollers: Two 100mm Rollers covered with Pure Dielectric Silicon Sleeve.

Pneumatic Cylinder: 40mm Bore x 80 mm Stroke.

Safety Interlocks

Zero Speed System: In case the Guide or Main Roller stops moving , the Generator Trips.

Spark Protection: In case of Spark in the Electrodes, the Generator will Trip.

Phase Protection: Phase Protection In the Event of any Phase Failure, the Generator will Switch Off Completely.

Discharge Station Door Open Interlock: When the Door Opens, the Generator will trip.

No Corona Interlock: In case of No Corona, A Visual / Audio Indication will be given.

Ozone Extraction System

Motors: 3 HP | 3 Phase | 415 V | 15 Amps.

Suction Capacity: 600 CFM.

Pressure: 16”.

Inlet: 2 x 50mm.

Outlet: 75mm.

Accessories

Guide Rollers: Two 75 mm Dynamically Balanced Aluminium Rollers

Cables: As per Installation Requirements.

Dyne Level Pens: 42 Dynes Disposable Pen.

Note: Design and Specifications are subjected to change without prior notice.

FTS 5000 Series

FTS 5000 Series

Specification

Treatment Width: 1700mm.

Roller Width: 1800mm.

Read MoreRequest Quote

FTS 6000 Series

Specification Sheet

Treatment Width: 1700mm.

Roller Width: 1800mm.

Line Speed: 80 meters per minute.

Dyne Level: 42-44 Dynes/cm.

No of Sides: Double.

Substrate: HDPE, LDPE, LLDPE and PP.

Gauge: 40-100 microns.

Generator

Electrical Input Requirements: 415VAC | 3Phase | 50Hz | 15 Amps.

Output Power: 4000 Watts.

Output Frequency: 20–40 Khz.

PLC System with MMI Display: Unitronics or Equivalent.

Transformer

MOC: Aluminium.

Output Voltage: 10 K Volts.

Interlocks: Spark Gap Interlock which trips the Generator when the Discharge Station High Voltage Wire Breaks during Operation.

Cooling: Transformer Oil [IS 335] | Quantity : 50 Litres

Discharge Station

Electrodes: Fin Type Electrode / Key Type*.

Main Rollers: Two 100mm Rollers covered with Pure Dielectric Silicon Sleeve.

Pneumatic Cylinder: 40mm Bore x 80 mm Stroke.

Safety Interlocks

Zero Speed System: In case the Guide or Main Roller stops moving , the Generator Trips.

Spark Protection: In case of Spark in the Electrodes, the Generator will Trip.

Phase Protection: Phase Protection In the Event of any Phase Failure, the Generator will Switch Off Completely.

Discharge Station Door Open Interlock: When the Door Opens, the Generator will trip.

No Corona Interlock: In case of No Corona, A Visual / Audio Indication will be given.

Ozone Extraction System

Motors: 3 HP | 3 Phase | 415 V | 15 Amps.

Suction Capacity: 600 CFM.

Pressure: 16”.

Inlet: 2 x 50mm.

Outlet: 75mm.

Accessories

Guide Rollers: Two 75 mm Dynamically Balanced Aluminium Rollers

Cables: As per Installation Requirements.

Dyne Level Pens: 42 Dynes Disposable Pen.

Note: Design and Specifications are subjected to change without prior notice.

FTS 6000 Series

FTS 6000 Series

Specification

Treatment Width: 2100mm.

Roller Width: 2200mm.

Read MoreRequest Quote

FTS 7000 Series

Specification Sheet

Treatment Width: 2100mm.

Roller Width: 2200mm.

Line Speed: 80 meters per minute.

Dyne Level: 44 Dynes/cm.

No of Sides: Double.

Substrate: HDPE, LDPE, LLDPE and PP.

Gauge: Unitronics or Equivalent.

Generator

Electrical Input Requirements: 415VAC | 3Phase | 50Hz | 15 Amps.

Output Power: 5000 Watts.

Output Frequency: 20–40 Khz.

System with MMI Display: Unitronics or Equivalent

Transformer

MOC: Aluminium.

Output Voltage: 10 K Volts.

Interlocks: Spark Gap Interlock which trips the Generator when the Discharge Station High Voltage Wire Breaks during Operation.

Cooling: Transformer Oil [IS 335] | Quantity : 50 Litres

Discharge Station

Electrodes: Fin Type Electrode.

Main Rollers: Two 125mm rollers covered with Pure Dielectric Silicon Sleeves with external Bearings

Pneumatic Cylinder: Two 100mm Rollers for Entry & Exit of Film.

Safety Interlocks

Zero Speed System: In case the Guide or Main Roller stops moving , the Generator Trips.

Spark Protection: In case of Spark in the Electrodes, the Generator will Trip.

Phase Protection: In the Event of any Phase Failure, the Generator will Switch Off Completely

Discharge Station Door Open Interlock: When the Door Opens, the Generator will trip.

No Corona Interlock: In case of No Corona, A Visual / Audio Indication will be given.

Ozone Extraction System

Motors: 5 HP | 3 Phase | 415 V | 15 Amps.

Suction Capacity: 900 CFM.

Inlet: 2 x 75mm.

Outlet: 75mm.

Accessories

Cables: As per Installation Requirements.

Dyne Level Pens: 42 Dynes Disposable Pen.

Note: Design and Specifications are subjected to change without prior notice.

FTS 7000 Series

FTS 7000 Series

Specification

Treatment Width: 2500mm.

Roller Width: 2600mm.

Read MoreRequest Quote

FTS 8000 Series

Specification Sheet

Treatment Width: 2500mm.

Roller Width: 2600mm.

Line Speed: 80 meters per minute.

Dyne Level: 44 Dynes/cm.

No of Sides: Double.

Substrate: HDPE, LDPE, LLDPE and PP.

Gauge: 40-100 microns.

Generator

Electrical Input Requirements: 415VAC | 3Phase | 50Hz | 15 Amps.

Output Power: 6000 Watts.

Output Frequency: 20–40 Khz.

System with MMI Display: Unitronics or Equivalent

Transformer

MOC: Aluminium.

Output Voltage: 10 K Volts.

Interlocks: Spark Gap Interlock which trips the Generator when the Discharge Station High Voltage Wire Breaks during Operation.

Cooling: Transformer Oil [IS 335] | Quantity : 50 Litres

Discharge Station

Electrodes: Fin Type Electrode.

Main Rollers: Two 150mm rollers covered with Pure Dielectric Silicon Sleeves with external Bearings

Pneumatic Cylinder: Two 125mm Rollers for Entry & Exit of Film.

Safety Interlocks

Zero Speed System: In case the Guide or Main Roller stops moving , the Generator Trips.

Spark Protection: In case of Spark in the Electrodes, the Generator will Trip.

Phase Protection: In the Event of any Phase Failure, the Generator will Switch Off Completely

Discharge Station Door Open Interlock: When the Door Opens, the Generator will trip.

No Corona Interlock: In case of No Corona, A Visual / Audio Indication will be given.

Ozone Extraction System

Motors: 5 HP | 3 Phase | 415 V | 15 Amps.

Suction Capacity: 900 CFM.

Inlet: 2 x 75mm.

Outlet: 100mm.

Accessories

Cables: As per Installation Requirements.

Dyne Level Pens: 42 Dynes Disposable Pen.

Note: Design and Specifications are subjected to change without prior notice.

FTS 8000 Series

FTS 8000 Series

Corona Treatment for Coating and Lamination

Specification

Output Power: 3000 Watts.

Output Frequency: 20–40 Khz.

Read MoreRequest Quote

FTS 3000 BR

Generator

Electrical Input Requirements: 415VAC | 3Phase | 50Hz | 15 Amps.

Output Power: 3000 Watts.

Output Frequency: 20–40 Khz.

System with MMI Display: Schneider.

Transformer

MOC: Al Powder Coated.

Output Voltage: 10 KVolts.

Interlocks: Spark Gap Interlock which trips the Generator when the Discharge Station High Voltage Wire Breaks during Operation.

Cooling: Transformer Oil

Safety Interlocks

Zero Speed System: In case the Guide or Main Roller stops moving , the Generator Trips.

Spark Protection: In case of Spark in the Electrodes, the Generator will Trip.

Phase Protection: In the Event of any Phase Failure, the Generator will Switch Off Completely

Discharge Station Door Open Interlock: When the Door Opens, the Generator will trip.

No Corona Interlock: In case of No Corona, A Visual/Audio Indication will be given.

Pneumatic Operated Split Box Assembly

Electrodes: 100mm Rollers Covered with Silicone Sleeves driven Externally by AC Motor.

Treating Rollers: 150mm Roller with External Drive Arrangement with Motor and Drive Synchronised with Machine Line Speed.

Guide Rollers: 75mm rollers for Entry & Exit of Film.

Ozone Extraction System

Motors: 3 HP | 3 Phase | 415 V | 15 Amps.

Inlet: 2 x 75mm.

Outlet: 100mm.

Accessories

Cables: As per Installation Requirements.

Dyne Level Pens: 44 Dynes Disposable Pen.

Note: Design and Specifications are subjected to change without prior notice.

FTS 3000 BR

FTS 3000 BR

Specification

Output Power: 6000 Watts.

Output Frequency: 20–40 Khz.

Read MoreRequest Quote

FTS 5000 BR

Generator

Electrical Input Requirements: 415VAC | 3Phase | 50Hz | 15 Amps.

Output Power: 6000 Watts.

Output Frequency: 20–40 Khz.

System with MMI Display: Delta Make.

Transformer

MOC: MS Powder Coated.

Output Voltage: 10 KVolts.

Interlocks: Spark Gap Interlock which trips the Generator when the Discharge Station High Voltage Wire Breaks during Operation.

Cooling: Transformer Oil

Safety Interlocks

Zero Speed System: In case the Guide or Main Roller stops moving , the Generator Trips.

Spark Protection: In case of Spark in the Electrodes, the Generator will Trip.

Phase Protection: In the Event of any Phase Failure, the Generator will Switch Off Completely

Discharge Station Door Open Interlock: When the Door Opens, the Generator will trip.

No Corona Interlock: In case of No Corona, A Visual/Audio Indication will be given.

Pneumatic Operated Split Box Assembly

Electrodes: Roller covered with Silicone Sleeves and driven Externally by AC Motor.

Treating Rollers: 200 mm Diameter SS 304 Roller with External Drive Arrangement with Complete Motor and Drive Synchronised with Speed of Machine.

Guide Rollers: 75mm rollers for Entry & Exit of Film.

Ozone Extraction System

Motors: 5 HP | 3 Phase | 415 V.

Inlet: 2 x 75mm.

Outlet: 100mm.

Accessories

Cables: As per Installation Requirements.

Dyne Level Pens: 44 Dynes Disposable Pen.

Note: Design and Specifications are subjected to change without prior notice.

FTS 5000 BR

Specification

Output Power: 5000 Watts.

Output Frequency: 20–40 Khz.

Read MoreRequest Quote

FTS 5000 CR

Generator

Electrical Input Requirements: 415VAC | 3Phase | 50Hz | 15 Amps.

Output Power: 5000 Watts.

Output Frequency: 20–40 Khz.

System with MMI Display: Delta or Equivalent.

Transformer

MOC: MS Powder Coated.

Output Voltage: 10 KVolts.

Interlocks: Spark Gap Interlock which trips the Generator when the Discharge Station High Voltage Wire Breaks during Operation.

Cooling: Transformer Oil

Safety Interlocks

Zero Speed System: In case the Guide or Main Roller stops moving , the Generator Trips.

Spark Protection: In case of Spark in the Electrodes, the Generator will Trip.

Phase Protection: In the Event of any Phase Failure, the Generator will Switch Off Completely

Discharge Station Door Open Interlock: When the Door Opens, the Generator will trip.

No Corona Interlock: In case of No Corona, A Visual/Audio Indication will be given.

Pneumatic Operated Split Box Assembly

Electrodes: 6 Nos Ceramic Electrodes**.

Treating Rollers: 200 mm SS 304 Roller with External Drive Arrangement including 1 Hp Motor, Gear Box and Drive which will be Synchronized with Line Speed.

Guide Rollers: 75mm rollers for Entry & Exit of Film.

Ozone Extraction System

Motors: 5 HP | 3 Phase | 415 V.

Inlet: 2 x 75mm.

Outlet: 100mm.

Accessories

Cables: As per Installation Requirements.

Dyne Level Pens: 44 Dynes Disposable Pen.

Note: Design and Specifications are subjected to change without prior notice.

FTS 5000 CR

FTS 5000 CR

Corona Treatment for 3D Items

Specification

Treatment Width: 20-125mm.

Line Speed: 25 m/min.

Read MoreRequest Quote

FTS 500 3D

Specification Sheet

Treatment Width: 20-125mm.

Line Speed: 25 meters per minute.

Dyne Level: 42 Dynes/cm.

Generator

Electrical Input Requirements: 230VAC | Single Phase | 50Hz | 5 Amps.

Output Power: 500 Watts.

Output Frequency: 20–40 Khz.

PLC: Schneider

Transformer

MOC: Aluminium Powder Coated.

Output Voltage: 10 K Volts.

Interlocks: Spark Gap Interlock which trips the Generator when the Discharge Station High Voltage Wire Breaks during Operation.

Cooling: Transformer Oil.

Discharge Station

Electrodes: Fin Type Electrode.

Main Rollers: Two 150mm rollers covered with Pure Dielectric Silicon Sleeves with external Bearings.

Pneumatic Cylinder: Two 125mm Rollers for Entry & Exit of Film.

Safety Interlocks

Zero Speed System: In case the Guide or Main Roller stops moving, the Generator Trips.

Spark Protection: In case of Spark in the Electrodes, the Generator will Trip.

Phase Protection: Single Phase Protection for Ozone Extraction Blower.

Discharge Station Door Open Interlock: When the Door Opens, the Generator will trip.

No Corona Interlock: In case of No Corona, A Visual/Audio Indication will be given.

Corona Discharge Unit

Electrodes: Flexible Wire suitable to Treat the Moulded Articles.

Conveyor System: 1200mm MS Powder Coated Delrin Slat Chain Conveyor with Housing and Operator Safety Interlocks.

Ozone Extraction System: 1 Hp. – 3 Phase MS Powder Coated Blower. 75mm Inlet and 75mm Outlet.

Accessories

Cables: As per Installation Requirements.

Dyne Level Pens: 42 Dynes Disposable Pen.

Note: Design and Specifications are subjected to change without prior notice.

FTS 500 3D

FTS 500 3D

Few of Our Esteemed Clientele
Kabra Extrusiontechnik LtdWindsor Machines LtdPositive Packaging Ind LtdAbhedya Industries LtdBalaji Plasto IndustriesFeno Plast LtdJagadish IndustriesWin-Ex Film Pvt LtdSiddhi PlasticsGlasso Pack P. LtdMegha PackagingDarshan PlasticsSri Bhavani Poly BagsLarsen & Toubro LtdVishakha Polyfab Pvt LtdKamakshi Flexiprint Pvt LtdIkon MultipackDSM Enterprises LtdNeo PolypackAshirwad EnterprisesKanchan PlasticsBakulesh FabricatorsL.N. Packaging P. LtdEco plast LtdKnack PolymersVimalachal Print & Pack (P) LtdGautam Polymer Pvt LtdSwastik Multi PackUma Polymers LtdHi Tech PolymersParikh Packaging Pvt LtdZydus Cadila Healthcare Ltd Ranjan PlasticsAbhi PlasticsHemant PlasticsMantra PackagingInnsale TeknikGurucharan Ltd+